4 QC6: Quantitative Test and Certification3

Ext. Barrel Module IFA002 - DAQ Run Number = 211

 

 

TileRow

Drop Before Gluing

Drop After Gluing

PMT 37, Cell D6, Fiber #18

9

86.4%

45.8%

 

11

86.3%

46.7%

PMT 17, Cell D5, Fiber #53

9

85.5%

36.0%

 

11

86.6%

47.2%

PMT 18, Cell D5, Fiber #63

9

88.4%

40.5%

 

11

88.7%

44.9%

PMT 18, Cell D5, Fiber #65

9

73.8%

32.5%

 

11

75.4%

26.4%

 

 

PMT

CELL

TileRow

Fiber #

Drop

Possible Problem

22

A14

3

5

39.8%

Coupling Related

22

A14

3

12

62.9%

Coupling Related

 

PMT

CELL

TileRow

Fiber #

Drop

Possible Problem

29

A15

1

28

38.9%

Coupling Related

12

A13

1

25

27.2%

Fiber Related

12

A13

3

25

24.0%

Fiber Related

38

D6

9

23

25.5%

Fiber Related

38

D6

11

23

23.8%

Fiber Related

38

D6

10

8

27.8%

Fiber Related

 

PMT

CELL

TileRow

Fiber #

Drop

Possible Problem

42

A16

1

47

44.4%

Fiber Related

42

A16

3

47

42.2%

Fiber Related

29

A15

1

13

19.4%

Fiber Related

29

A15

3

13

29.9%

Fiber Related

41

A13

2

35

30.9%

Fiber Related

For Cell A16 (PMT 41, TileRow 2) the fiber #28 which had ~34% of Drop its profile was extracted and put it again obtaining a Drop ~30.9%, which indicates that the Optical problem could be related to the fiber itself.

 

Files: raw_run211.hbook - hist_run13.ps - hist_run211.ps - raw_data_run211.ps - OPTICAL PROBLEMS RUN211.txt - OPTICAL PROBLEMS RUN13.txt

Josep Flix (jflix@ifae.es)

Ilya Korolkov (korolkov@ifae.es)